Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.600
Filtrar
1.
ANZ J Surg ; 94(4): 724-732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572937

RESUMO

INTRODUCTION: Surgical glove perforation has been linked to a double-fold increased risk of surgical site infection. Infection in the context of arthroplasty can have devastating consequences. In orthopaedics, use of polymethyl methacrylate (PMMA) bone cement is commonplace, and the impact on glove strength and perforation risk is not fully understood. This study aimed to examine the resistance to perforation and thickness of gloves following PMMA exposure, in accordance with the International Organization for Standardization (ISO) standard for glove integrity. METHODS: Pairs of gloves were separated and randomly sorted into exposure and control groups. Twenty pairs of latex and 40 pairs of polyisoprene gloves were used. Exposure group glove cuffs were in contact with cement from a single surface of the glove for 13 min as cement cured. Force to perforation and glove thickness were tested in accordance with ISO guidelines. RESULTS: Latex gloves were found to have a significantly increased force to perforation following PMMA exposure (10.26 Newtons (N) vs. 9.81 N, P = 0.048). Both polyisoprene under- and over-gloves were shown to have no significant change in strength to perforation post exposure (9.69 N vs. 9.83 N, P = 0.561, and 10.26 N vs. 10.65 N, P = 0.168, respectively). All groups were over the ISO standard minimum strength of 5 N. CONCLUSIONS: Exposure of latex and polyisoprene surgical gloves to PMMA bone cement does not appear to increase glove perforation risk and rather may improve natural rubber latex glove strength. This study supports the use of latex and polyisoprene surgical gloves in procedures that involve the handling of PMMA bone cement.


Assuntos
Luvas Cirúrgicas , Ortopedia , Humanos , Polimetil Metacrilato/efeitos adversos , Cimentos Ósseos/efeitos adversos , Látex
2.
Clin Exp Dent Res ; 10(2): e842, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38597122

RESUMO

OBJECTIVE: To investigate the effect of common beverages on four currently used provisional restoration materials: Protemp®4, Integrity®, polymethyl methacrylate (PMMA) block, and acrylic resin. Flowable resin composite is included as a control group. MATERIALS AND METHODS: Each material was formed into disks of 10-mm diameter and 4-mm thickness (N = 40) by loading the material into acrylic molds. The exposed surface in the mold was covered using a glass slide to prevent an oxygen inhibition layer, and polymerization then proceeded. The solidified disks were placed in distilled water for 24 h. These samples (n = 8) were then immersed for 14 days in one of four different beverages: water, orange juice, cola, and coffee. Changes in color dimension, hardness, and roughness were observed and then analyzed using two-way repeated analysis of variance. RESULTS: The provisional materials had more obvious changes in all three color dimensions than the flowable resin composite. Integrity showed the biggest changes, followed by acrylic resin and PMMA block, whereas Protemp had the smallest changes. The hardness of all the materials significantly decreased after immersion in any of the beverages for 14 days. There were no changes in surface roughness when the materials were immersed in distilled water. The surface roughness of the PMMA block significantly decreased in orange juice whereas that of Integrity and acrylic resin significantly increased in cola. CONCLUSION: Different kinds of provisional materials had different degrees of staining due to their composition. Moisture had a significant influence on the hardness of materials, and the acidity of cola significantly roughened the surface of the provisional materials.


Assuntos
Bebidas , Polimetil Metacrilato , Resinas Acrílicas , Café , Água
3.
São Paulo; s.n; 20240301. 98 p.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1532845

RESUMO

Este estudo tem por objetivo avaliar a influência do tratamento térmico (TT) a seco pós-cura sobre as propriedades mecânicas e ópticas de resinas acrílicas ativadas quimicamente (Dencôr e Duralay) e resinas bisacrílicas (Protemp 4 e Primma Art). Os corpos de prova (cps) foram confeccionados nas dimensões de 12mm de diâmetro e 1mm de espessura em matriz de poliacetal. Após a confecção, as resinas foram divididas em grupos experimentais onde receberam TT, pelo período de 10 minutos, 70 C (TT70), a 100 C (TT100) ou a 130 C (TT130) e as pertencentes ao grupo controle foram mantidas a 24 C (CTL) pelo mesmo período. A diferença de cor (CIEDE2000 - E00) e o parâmetro de translucidez (PT) foram avaliados utilizando um espectrofotômetro. A resistência ao manchamento após imersão em água, vinho tinto e café durante 30 dias também foi avaliada por meio da E00. A avaliação de microdureza Knoop (KHN) foi realizada no microdurômetro e a análise da resistência à flexão biaxial (RFB) teve o auxílio da máquina de ensaio universal pelo método pistão sobre três esferas. O TT não teve influência sobre a RFB. O grupo TT130 produziu valores de KHN maiores que os demais grupos. Todos os TT acarretaram um aumento significativo no E00, com exceção do grupo TT70 da Dencôr e da Protemp. O TT na Dencôr resultou em aumento do PT, e para a Duralay e Protemp, uma redução do PT em TT100 e TT130. No geral, as resinas acrílicas apresentaram um aumento da estabilidade de cor ao serem submetidas ao TT. Para as resinas bisacrílicas, o TT não influenciou a resistência ao manchamento. O presente trabalho concluiu que os TTs produziram aumento na KHN (TT130) e não influenciaram a RFB. O TT e a imersão em corantes levaram a uma maior diferença de cor, todavia dentro do limite de aceitabilidade. Houve aumento pontual da resistência ao manchamento das resinas.


Assuntos
Temperatura , Resinas Acrílicas , Tratamento Térmico , Polimetil Metacrilato
4.
BMC Oral Health ; 24(1): 357, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509542

RESUMO

BACKGROUND: This study compared the impact of thermal cycling on the flexural strength of denture-base materials produced through conventional and digital methods, using both subtractive and additive approaches. METHODS: In total, 60 rectangular specimens were fabricated with specific dimensions for flexural strength tests. The dimensions were set according to the International Organization for Standardization (ISO) guideline 20795-1:2013 as 64 × 10 × 3.3 ± 0.2 mm. Specimens from each material group were divided into two subgroups (thermal cycled or nonthermal cycled, n = 10/group). We used distinct methods to produce three different denture-base materials: Ivobase (IB), which is a computer-aided-design/computer-aided-manufacturing-type milled pre-polymerized polymethyl methacrylate resin disc; Formlabs (FL), a 3D-printed denture-base resin; and Meliodent (MD), a conventional heat-polymerized acrylic. Flexural strength tests were performed on half of the samples without a thermal-cycle procedure, and the other half were tested after a thermal cycle. The data were analyzed using a two-way analysis of variance and a post hoc Tukey test (α = 0.05). RESULTS: Based on the results of flexural-strength testing, the ranking was as follows: FL > IB > MD. The effect of thermal aging was statistically significant for the FL and IB bases, but not for the MD base. CONCLUSIONS: Digitally produced denture bases exhibited superior flexural strength compared with conventionally manufactured bases. Although thermal cycling reduced flexural strength in all groups, the decrease was not statistically significant in the heat-polymerized acrylic group.


Assuntos
Resistência à Flexão , Temperatura Alta , Humanos , Resinas Acrílicas , Bases de Dentadura , Teste de Materiais , Polimetil Metacrilato , Propriedades de Superfície
5.
Artigo em Russo | MEDLINE | ID: mdl-38549407

RESUMO

OBJECTIVE: To evaluate mechanical strength of three methods of polymethyl methacrylate skull implant fixation in two experimental models. MATERIAL AND METHODS: The first experiment was performed on a plastic model that was as close as possible to bone in structural characteristics. The second experiment was performed on a biological specimen (a ram's head). We assessed the quality of implant fixation to bone window edges by craniofixes, ties and microscrews and lateral intercortical screws. RESULTS: Craniofixes are feasible for small flat flaps, but not advisable for wide highly curved implants. They are also the most expensive method of fixation. Implant fixation by ties and microscrews is a universal method comparable in price to craniofix. Lateral intercortical fixation is effective both for small flat implants and wide implants with large curvature. However, this method is not always applicable. CONCLUSION: Combined fixation by lateral intercortical screws and ties allows for the most effective fixation while reducing the overall price of consumables.


Assuntos
Polimetil Metacrilato , Titânio , Masculino , Animais , Ovinos , Polimetil Metacrilato/química , Crânio/cirurgia , Próteses e Implantes , Craniotomia/métodos
6.
ACS Biomater Sci Eng ; 10(4): 2398-2413, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38477550

RESUMO

In vertebroplasty and kyphoplasty, bioinert poly(methyl methacrylate) (PMMA) bone cement is a conventional filler employed for quick stabilization of osteoporotic vertebral compression fractures (OVCFs). However, because of the poor osteointegration, excessive stiffness, and high curing temperature of PMMA, the implant loosens, the adjacent vertebrae refracture, and thermal necrosis of the surrounding tissue occurs frequently. This investigation addressed these issues by incorporating the small intestinal submucosa (SIS) into PMMA (SIS-PMMA). In vitro analyses revealed that this new SIS-PMMA bone cement had improved porous structure, as well as reduced compressive modulus and polymerization temperature compared with the original PMMA. Furthermore, the handling properties of SIS-PMMA bone cement were not significantly different from PMMA. The in vitro effect of PMMA and SIS-PMMA was investigated on MC3T3-E1 cells via the Transwell insert model to mimic the clinical condition or directly by culturing cells on the bone cement samples. The results indicated that SIS addition substantially enhanced the proliferation and osteogenic differentiation of MC3T3-E1 cells. Additionally, the bone cement's biomechanical properties were also assessed in a decalcified goat vertebrae model with a compression fracture, which indicated the SIS-PMMA had markedly increased compressive strength than PMMA. Furthermore, it was proved that the novel bone cement had good biosafety and efficacy based on the International Standards and guidelines. After 12 weeks of implantation, SIS-PMMA indicated significantly more osteointegration and new bone formation ability than PMMA. In addition, vertebral bodies with cement were also extracted for the uniaxial compression test, and it was revealed that compared with the PMMA-implanted vertebrae, the SIS-PMMA-implanted vertebrae had greatly enhanced maximum strength. Overall, these findings indicate the potential of SIS to induce efficient fixation between the modified cement surface and the host bone, thereby providing evidence that the SIS-PMMA bone cement is a promising filler for clinical vertebral augmentation.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Humanos , Cimentos Ósseos/farmacologia , Cimentos Ósseos/química , Polimetil Metacrilato/farmacologia , Polimetil Metacrilato/química , Osteogênese , Fraturas da Coluna Vertebral/cirurgia , Coluna Vertebral
7.
Int J Mol Sci ; 25(5)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38474234

RESUMO

Developmental engineering (DE) involves culturing various cells on modular scaffolds (MSs), yielding modular tissues (MTs) assembled into three-dimensional (3D) tissues, mimicking developmental biology. This study employs an integrated approach, merging experimental and mathematical methods to investigate the biological processes in MT cultivation and assembly. Human dermal fibroblasts (HDFs) were cultured on tissue culture plastics, poly(lactic acid) (PLA) discs with regular open structures, or spherical poly(methyl methacrylate) (PMMA) MSs, respectively. Notably, HDFs exhibited flattened spindle shapes when adhered to solid surfaces, and complex 3D structures when migrating into the structured voids of PLA discs or interstitial spaces between aggregated PMMA MSs, showcasing coordinated colonization of porous scaffolds. Empirical investigations led to power law models simulating density-dependent cell growth on solid surfaces or voids. Concurrently, a modified diffusion model was applied to simulate oxygen diffusion within tissues cultured on solid surfaces or porous structures. These mathematical models were subsequently combined to explore the influences of initial cell seeding density, culture duration, and oxygen diffusion on MT cultivation and assembly. The findings underscored the intricate interplay of factors influencing MT design for tissue assembly. The integrated approach provides insights into mechanistic aspects, informing bioprocess design for manufacturing MTs and 3D tissues in DE.


Assuntos
Engenharia Tecidual , Tecidos Suporte , Humanos , Tecidos Suporte/química , Engenharia Tecidual/métodos , Polimetil Metacrilato/química , Poliésteres , Oxigênio
8.
Neurosurg Rev ; 47(1): 112, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38467929

RESUMO

This study presents a critical analysis of complications following cranioplasty (CP) after decompressive hemicraniectomy, focusing on autologous, polymethylmethacrylate (PMMA), and computer-aided design (CAD) implants. The analysis encompasses a retrospective bicenter assessment, evaluating factors influencing surgical outcomes and emphasizing the significance of material selection in minimizing postoperative complications. The study's comprehensive examination of complication rates associated with various implant materials contributes significantly to understanding CP outcomes. While polymethylmethacrylate (PMMA) and autologous bone flaps (ABFs) exhibited higher rates of surgical site infection (SSI) and explantation, a meta-analysis revealed a contrasting lower infection rate for polyether ether ketone (PEEK) implants. The study underscores the critical role of material selection in mitigating postoperative complications. Despite its strengths, the study's retrospective design, reliance on data from two centers, and limited sample size pose limitations. Future research should prioritize prospective, multicenter studies with standardized protocols to enhance diagnostic accuracy and treatment efficacy in CP procedures.


Assuntos
Craniectomia Descompressiva , Polimetil Metacrilato , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Craniectomia Descompressiva/efeitos adversos , Craniectomia Descompressiva/métodos , Crânio/cirurgia , Complicações Pós-Operatórias/cirurgia , Desenho Assistido por Computador
9.
Int J Prosthodont ; 37(7): 133-141, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498865

RESUMO

PURPOSE: To evaluate the flexural strength (FS) and microhardness of various CAD/CAM restorative materials intended for definitive use. The effect of hydrothermal aging on the mechanical properties of these materials was also investigated. MATERIALS AND METHODS: A total of 210 bar-shaped specimens (17 × 4 × 1.5 mm ± 0.02 mm) were fabricated via either subtractive manufacturing (SM) methods-reinforced composite resin (SM-CR), polymer-infiltrated ceramic network (SM-PICN), fine-structured feldspathic ceramic (SMFC), nanographene-reinforced polymethyl methacrylate (PMMA; SM-GPMMA), PMMAbased resin (SM-PMMA)-or additive manufacturing (AM) methods with urethane acrylate-based resins (AM-UA1 and AM-UA2). Specimens were then divided into two subgroups (nonaged or hydrothermal aging; n = 15). A three-point flexural strength test was performed, and five specimens from the nonaged group were submitted to microhardness testing. Specimens were subjected to 10,000 thermal cycles, and the measurements were repeated. RESULTS: Regardless of aging, SM-CR had the highest FS (P < .001), followed by SM-GPMMA (P ≤ .042). In nonaged groups, AM-UA2 had a lower FS than all other materials except SM-FC (P = 1.000). In hydrothermal aging groups, AM specimens had lower FS values than other materials, except SM-PMMA. With regard to microhardness, there was no significant difference found between any of the tested materials (P ≥ .945) in the nonaged and hydrothermal aging groups. CONCLUSIONS: The effect of hydrothermal aging on FS varied depending on the type of restorative material. Regardless of aging condition, SM-CR showed the highest FS values, whereas SM-FC had the highest microhardness. Hydrothermal aging had no significant influence on the microhardness of the tested materials.


Assuntos
Resistência à Flexão , Polimetil Metacrilato , Materiais Dentários , Resinas Compostas , Polímeros , Teste de Materiais , Propriedades de Superfície , Desenho Assistido por Computador
10.
BMC Ophthalmol ; 24(1): 103, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443841

RESUMO

PURPOSE: To measure the dislocation forces in relation to haptic material, flange size and needle used. SETTING: Hanusch Hospital, Vienna, Austria. DESIGN: Laboratory Investigation. METHODS, MAIN OUTCOME MEASURES: 30 G (gauge) thin wall and 27 G standard needles were used for a 2 mm tangential scleral tunnel in combination with different PVDF (polyvinylidene fluoride) and PMMA (polymethylmethacrylate haptics). Flanges were created by heating 1 mm of the haptic end, non-forceps assisted in PVDF and forceps assisted in PMMA haptics. The dislocation force was measured in non-preserved cadaver sclera using a tensiometer device. RESULTS: PVDF flanges achieved were of a mushroom-like shape and PMMA flanges were of a conic shape. For 30 G needle tunnels the dislocation forces for PVDF and PMMA haptic flanges were 1.58 ± 0.68 N (n = 10) and 0.70 ± 0.14 N (n = 9) (p = 0.003) respectively. For 27 G needle tunnels the dislocation forces for PVDF and PMMA haptic flanges were 0.31 ± 0.35 N (n = 3) and 0.0 N (n = 4), respectively. The flange size correlated with the occurring dislocation force in experiments with 30 G needle tunnels (r = 0.92), when flanges were bigger than 384 micrometres. CONCLUSIONS: The highest dislocation forces were found for PVDF haptic flanges and their characteristic mushroom-like shape for 30 G thin wall needle scleral tunnels. Forceps assisted flange creation in PMMA haptics did not compensate the disadvantage of PMMA haptics with their characteristic conic shape flange.


Assuntos
Polímeros de Fluorcarboneto , Tecnologia Háptica , Lentes Intraoculares , Polivinil , Humanos , Polimetil Metacrilato , Esclera/cirurgia
11.
J Oral Sci ; 66(2): 120-124, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38494704

RESUMO

PURPOSE: To evaluate the flexural properties of repaired poly(methylmethacrylate) (PMMA) denture base materials for computer-aided design/computer-aided manufacturing (CAD-CAM) and to compare them with heat-activated polymerized PMMA. METHODS: A total of 288 specimens (65 × 10 × 2.5 mm) were prepared using both CAD-CAM and conventional blocks and repaired using autopolymerizing and visible-light polymerizing (VLC) materials. Microwave energy, water storage and hydroflask polymerization were applied as additional post-polymerization cycles after the repair process. The flexural strength (FS) of the specimens was evaluated using the three-point bending test. Data were evaluated statistically using 2-way ANOVA followed by Bonferroni's correction to determine the significance of differences between the groups (P ≤ 0.05). RESULTS: The FS of the denture base materials for CAD-CAM was significantly higher than that for the heat-activated group (P ≤ 0.05). The FS was significantly highest when microwave energy was used for the post-polymerization cycle. The FS values for all groups repaired with VLC resin were significantly lower than for the autopolymerization group (P ≤ 0.05). CONCLUSION: The flexural properties of denture base materials for CAD-CAM repaired using autopolymerizing acrylic resins can recover by 50-70%. Additional post-polymerization cycles for autopolymerizing repair resin can be suggested to improve the clinical service properties of repaired dentures.


Assuntos
Materiais Dentários , Resistência à Flexão , Polimetil Metacrilato , Bases de Dentadura , Teste de Materiais , Resinas Acrílicas , Desenho Assistido por Computador , Reparação em Dentadura , Propriedades de Superfície
12.
J Mech Behav Biomed Mater ; 154: 106501, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38531182

RESUMO

OBJECTIVE: The influence of various aging protocols, representing and accelerating influences present in the dental context, on possible changes in the microstructure and mechanical properties of thermoplastics was investigated. In order to minimize the complexity of the systems, first pure polymers and then later the equivalent dental polymeric materials were analyzed. MATERIALS AND METHODS: Pure polymers (Poly(methyl methacrylate) - PMMA, Polyoxymethylene homopolymer - POM-H, Polyether ether ketone - PEEK, Nylon 12 - PA12, Polypropylene - PP) were analyzed before as well as after applying different aging protocols relevant to the oral environment (ethanol, thermocycling, alkaline and acidic setting) by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). The thermoanalytical parameters used were glass transition temperature (Tg), melting peak and crystallization peak temperature (Tpm, Tpc) and decomposition behavior. In a second step selected commercially available dental products (Telio CAD - PMMAD, Zirlux Acetal - POMD, Juvora Natural Dental Disc - PEEKD) aged by the protocol that previously showed strong effects were examined and additionally tested for changes in their Vickers and Martens hardness by Mann-Whitney-U test. RESULTS: The combinations of pure polymers and viable aging protocols analyzed within this study were identified via TGA or DSC as PA12 & thermocycling, POM-H & denture cleanser/lactic acid/ethanol, PP & lactic acid. The dental polymeric materials PMMAD and POMD due to aging in lactic acid showed slight but significantly (p < 0.01) reduced Vickers and partly Martens hardness. PEEK showed the greatest material resistance within this study.


Assuntos
Benzofenonas , Mustelidae , Polimetil Metacrilato , Animais , Polimetil Metacrilato/química , Teste de Materiais , Dureza , Polímeros/química , Polietilenoglicóis/química , Cetonas/química , Etanol , Ácido Láctico , Materiais Dentários , Propriedades de Superfície
13.
Clin Exp Dent Res ; 10(2): e869, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38433287

RESUMO

OBJECTIVE: This study aimed to compare the color change of computer-aided design (CAD)/computer-aided manufacturing (CAM) polymethyl methacrylate (PMMA) denture teeth and conventional acrylic teeth after immersion in three staining beverages (coffee, red tea, and cola) for a day, 7 days, and 30 days. MATERIALS AND METHODS: Group 1: Conventional acrylic teeth (n = 32). Group 2: Milled CAD/CAM teeth out of PMMA disc (n = 32). The specimens of each material were further divided into four subgroups: (1) Control group, distilled water (n = 16). (2) Red tea solution (n = 16). (3) Coffee solution (n = 16). (4) Cola (n = 16). The color change ( ∆ E $\unicode{x02206}E$ ) was assessed using a spectrophotometer at four time points: at the baseline (t0 ), on the 1st day (t1 ), on the 7th day (t2 ), and the 30th day (t3 ) of immersion. Kolmogorov-Smirnov test was applied, followed by performing independent samples t test, one-way analysis of variance and post-hoc Tukey tests to compare the color change values at different time points. RESULTS: The mean score of NBS values of the coffee solution indicates perceivable color change at the end of the 30th day in the conventional acrylic teeth group. It was 0.843 ± 0.395 at t1 , then increased to 1.017 ± 0.477 at t2 and to 2.259 ± 1.059 at t3 . There is a statistically significant difference (p < 0.05) in color change values between both tooth types at the end of the 30th day of immersion in red tea solution and a statistically significant difference at the end of the 7th day (p < 0.05) and the 30th day (p < 0.05) of immersion in coffee solution. CONCLUSIONS: CAD/CAM PMMA teeth are more color stable than conventional acrylic teeth after 30 days of immersion in coffee and red tea solution.


Assuntos
Café , Polimetil Metacrilato , Bebidas , Desenho Assistido por Computador , Coloração e Rotulagem , Dentaduras , Chá
14.
PLoS One ; 19(3): e0299325, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38457423

RESUMO

PURPOSE: Vertebral compression fractures are often treated with vertebroplasty, and filling the injured vertebrae with bone cement is a key part of vertebroplasty. This meta-analysis was performed to compare the clinical efficacy and safety of mineralized collagen-polymethylmethacrylate (MC-PMMA) and polymethylmethacrylate (PMMA) bone cement in the treatment of vertebral compression fractures by vertebroplasty. METHODS: A computerized search of the published literature on mineralized collagen-polymethylmethacrylate and polymethylmethacrylate bone cement in the treatment of vertebral compression fractures was conducted in the China National Knowledge Infrastructure (CNKI), Wanfang database, PubMed, Embase, and Cochrane Library. The search was carried out from the time the database was created to March 2023 and 2 researchers independently conducted literature searches to retrieve a total of 884 studies, of which 12 were included in this meta-analysis. Cochrane systematic review methods were used to assess the quality of the literature and a meta-analysis was performed using ReviewManager 5.4 software. RESULTS: The results of the present meta-analysis showed that in postoperative adjacent vertebral fractures [OR = 0.25; 95% CI (0.15, 0.41)], postoperative cement leakage [OR = 0.45; 95% CI (0.30, 0.68)], Oswestry Disability Index (ODI) scores in the first 3 days after surgery [OR = -0.22; 95% CI (-0.42, -0.03)], ODI score at 6-12 months postoperatively [OR = -0.65; 95% CI (-0.97, -0.32)], visual analog scale (VAS) score at 6-12 months postoperatively [OR = -0.21; 95% CI (-0.46, 0.04)], and 1-year postoperative CT values [OR = 5.56; 95% CI (3.06, 8.06)], the MC-PMMA bone cement group was superior to the PMMA bone cement group. However, the differences between the two groups were not statistically different in terms of cement filling time, cement filling volume, operation time, intraoperative bleeding, hospitalization time, postoperative (<1 week, 3-6 months) vertebral body posterior convexity Cobb's angle, postoperative (<1 week, 6-12 months) vertebral body anterior margin relative height, postoperative (≤3 days, 1-3 months) pain VAS score and postoperative (1-3 months) ODI score. CONCLUSIONS: Compared with PMMA bone cement, the application of MC-PMMA bone cement is advantageous in reducing postoperative complications (adjacent vertebral fracture rate, cement leakage rate), pain relief, and functional recovery in the long-term postoperative period (>6 months), but there is still a need for more high-quality randomized controlled studies to provide more adequate evidence.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Cimentos Ósseos/uso terapêutico , Cimentos Ósseos/química , Colágeno , Fraturas por Compressão/cirurgia , Cifoplastia/métodos , Fraturas por Osteoporose/cirurgia , Dor/tratamento farmacológico , Polimetil Metacrilato/uso terapêutico , Polimetil Metacrilato/química , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento
15.
ACS Biomater Sci Eng ; 10(4): 2151-2164, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38453640

RESUMO

Poly(methyl methacrylate) (PMMA) is commonly used for dental dentures, but it has the drawback of promoting oral health risks due to oral bacterial adhesion. Recently, various nanoparticles have been incorporated into PMMA to tackle these issues. This study aims to investigate the mechanophysical and antimicrobial adhesive properties of a denture resin by incorporating of nanoclay into PMMA. Specimens were prepared by adding 0, 1, 2, and 4 wt % surface-modified nanoclay (Sigma) to self-polymerizing PMMA denture resin. These specimens were then evaluated using FTIR, TGA/DTG, and FE-SEM with EDS. Various mechanical and surface physical properties, including nanoindentation, were measured and compared with those of pure PMMA. Antiadhesion experiments were conducted by applying a Candida albicans (ATCC 11006) suspension to the surface of the specimens. The antiadhesion activity of C. albicans was confirmed through a yeast-wall component (mannan) and mRNA-seq analysis. The bulk mechanical properties of nanoclay-PMMA composites were decreased compared to those of pure PMMA, while the flexural strength and modulus met the ISO 20795-1 requirement. However, there were no significant differences in the nanoindentation hardness and elastic modulus. The surface energy revealed a significant decrease at 4 wt % nanoclay-PMMA. The antiadhesion effect of Candida albicans was evident along with nanoclay content in the nanocomposites and confirmed by the reduced attachment of mannan on nanoclay-PMMA composites. mRNA-seq analysis supported overall transcriptome changes in altering attachment and metabolism behaviors on the surface. The nanoclay-PMMA materials showed a lower surface energy as the content increased, leading to an antiadhesion effect against Candida albicans. These findings indicate that incorporating nanoclay into PMMA surfaces could be a valuable strategy for preventing the fungal biofilm formation of denture base materials.


Assuntos
Adesivos , Polimetil Metacrilato , Mananas , Teste de Materiais , Dentaduras , RNA Mensageiro
16.
Water Res ; 254: 121397, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38461599

RESUMO

Municipal wastewater treatment plants (WWTPs) play a crucial role in the collection and redistribution of plastic particles from both households and industries, contributing to their presence in the environment. Previous studies investigating the levels of plastics in WWTPs, and their removal rates have primarily focused on polymer type, size, shape, colour, and particle count, while comprehensive understanding of the mass concentration of plastic particles, particularly those <1 µm (nanoplastics), remains unclear and lacking. In this study, pyrolysis gas chromatography-mass spectrometry was used to simultaneously determine the mass concentration of nine selected polymers (i.e., polyethylene (PE), polypropylene (PP), polystyrene (PS), poly(ethylene terephthalate) (PET), nylon 6, nylon 66, polyvinylchloride (PVC), poly(methyl methacrylate) (PMMA) and polycarbonate (PC)) below 1 µm in size across the treatment processes or stages of three WWTPs in Australia. All the targeted nanoplastics were detected at concentrations between 0.04 and 7.3 µg/L. Nylon 66 (0.2-7.3 µg/L), PE (0.1-6.6 µg/L), PP (0.1-4.5 µg/L), Nylon 6 (0.1-3.6 µg/L) and PET (0.1-2.2 µg/L), were the predominant polymers in the samples. The mass concentration of the total nanoplastics decreased from 27.7, 18 and 9.1 µg/L in the influent to 1, 1.4 and 0.8 µg/L in the effluent, with approximate removal rates of 96 %, 92 % and 91 % in plants A, B and C, respectively. Based on annual wastewater effluent discharge, it is estimated that approximately 24, 2 and 0.7 kg of nanoplastics are released into the environment per year for WWTPs A, B and C, respectively. This study investigated the mass concentrations and removal rates of nanoplastics with a size range of 0.01-1 µm in wastewater, providing important insight into the pollution levels and distribution patterns of nanoplastics in Australian WWTPs.


Assuntos
Caprolactama/análogos & derivados , Polímeros , Poluentes Químicos da Água , Purificação da Água , Águas Residuárias , Microplásticos , Nylons , Pirólise , Cromatografia Gasosa-Espectrometria de Massas , Austrália , Plásticos/análise , Polipropilenos/análise , Polimetil Metacrilato , Polietilenos , Poluentes Químicos da Água/química , Monitoramento Ambiental
17.
Colloids Surf B Biointerfaces ; 237: 113864, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522283

RESUMO

Electrospun polymer scaffolds have gained prominence in biomedical applications, including tissue engineering, drug delivery, and wound dressings, due to their customizable properties. As the interplay between cells and materials assumes fundamental significance in biomaterials research, understanding the relationship between fiber properties and cell behaviour is imperative. Nevertheless, altering fiber properties introduces complexity by intertwining mechanical and surface chemistry effects, challenging the differentiation of their individual impacts on cell behaviour. Core-shell fibers present an appealing solution, enabling the control of mechanical properties of scaffolds, flexibility in material and drug selection, efficient encapsulation, strong protection of bioactive drugs against harsh environments, and controlled, prolonged drug release. This study addresses a key challenge in core-shell fiber design related to the blending effect between core and shell polymers. Two types of fibers, PMMA and core-shell PC-PMMA, were electrospun, and thorough analyses confirmed the desired core-shell structure in PC-PMMA fibers. Surface chemistry analysis revealed PC diffusion to the PMMA shell of the core-shell fiber during electrospinning, subsequently prompting an investigation of the fiber's surface potential. Conducting cellular studies on osteoblasts by super-resolution confocal microscopy provided insights into the direct influence of interfacial polymer blending and, consequently, altered fiber surface and mechanical properties on cell focal adhesion points, bridging the gap between material attributes and cell responses in core-shell fibers.


Assuntos
Polímeros , Polimetil Metacrilato , Polímeros/química , Polimetil Metacrilato/química , Adesões Focais , Engenharia Tecidual , Materiais Biocompatíveis/química , Tecidos Suporte/química
18.
J Dent ; 142: 104865, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38311017

RESUMO

OBJECTIVES: To evaluate the fracture strength and linear elongation at break of three-units fixed partial dentures (FPDs) fabricated with traditional and new materials for fixed prosthodontics before and after ageing. METHODS: Sixty models of three-units FPDs were fabricated and cemented onto a Co-Cr model simulating the replacement of a maxillary second premolar. The samples were randomly divided into 3 groups: metal-ceramic (MCR), graphene-doped polymethylmethacrylate (PMMA-GR) and polymethylmethacrylate (PMMA). Half of the samples were directly subjected to fracture test, while the remaining half underwent an ageing process and then a fracture loading test using an electrodynamic testing machine. Fracture load and elongation at break values were taken and statistically analysed. RESULTS: Significant differences were detected between the different materials (p<0.05). All groups showed a reduction of the fracture load and elongation at break values after ageing, but not statistically significant, except for PMMA group (p = 2.012e-19) (p = 3.8e-11). CONCLUSIONS: MCR and PMMA-GR three-units FPDs showed higher fracture strength and lower elongation at break compared to PMMA. MCR and PMMA-GR had higher resistance to ageing processes compared to PMMA. CLINICAL SIGNIFICANCE: PMMA-GR could be considered a material for long-term provisional restorations as its mechanical behaviour and ageing resistance are more like MCR than PMMA.


Assuntos
Resistência à Flexão , Grafite , Polimetil Metacrilato , Teste de Materiais , Cerâmica , Prótese Parcial Fixa , Falha de Restauração Dentária , Análise do Estresse Dentário , Porcelana Dentária
19.
Int J Nanomedicine ; 19: 1273-1285, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38348176

RESUMO

Purpose: To investigate the inhibition of Streptococcus mutans (S.mutans) and its biofilm by AgBr-nanoparticles (NP) @CTMAB (cetyltrimethyl-ammonium bromide) and evaluate the changes in Polymethyl methacrylate (PMMA)'s surface roughness (Ra), microhardness, and flexural strength during prolonged immersion in AgBr-NP@CTMAB for application in the denture cleaning industry. Patients and Methods: The antibacterial activity of AgBr-NP@CTMAB against S.mutans was measured colony formation assay, OD600 and laser confocal microscopy. Changes in the specimens' values for surface roughness, microhardness, and flexural strength (MPa) were measured after immersion solutions for 180 or 360 days. Results: The AgBr-NP@CTMAB solution exhibited a robust antibacterial effect on planktonic S. mutans, with a minimum bactericidal concentration of 5 µg/mL. The 10 µg/mL AgBr-NP@CTMAB solution efficiently inhibited S. mutans biofilm formation. (2) No significant difference in surface roughness after immersion in AgBr-NP@CTMAB (10 µg/mL and 20 µg/mL) comparing with distilled water (P > 0.05) and Polident had significantly higher than distilled water (P < 0.05). There was a significant decrease in the surface hardness of the PMMA specimens that were immersed in the Polident compared with those in distilled water (P < 0.05). While, no significant differences in surface hardness after immersion in the AgBr-NP@CTMAB (P > 0.05). The result of flexural strength suggested that there was no statistically significant difference (P < 0.05) between AgBr-NP@CTMAB as well as Polident and water. Conclusion: AgBrNP@CTMAB can efficiently inhibit the growth of plankton S.mutans and biofilm formation, without affecting the flexural strength, microhardness, or surface roughness of PMMA. Therefore, AgBrNP@CTMAB holds promise as a new denture cleaning agent.


Assuntos
Boratos , Nanopartículas , Polimetil Metacrilato , Sulfatos , Dureza , Resistência à Flexão , Streptococcus mutans , Bases de Dentadura , Água , Antibacterianos/farmacologia , Propriedades de Superfície , Teste de Materiais
20.
BMC Oral Health ; 24(1): 248, 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38368396

RESUMO

INTRODUCTION: The prevalence of adults with partially dental arches is expected to be more than imagined and patients requiring replacement of missing teeth are slowly increasing in number too. Removable partial dentures are known to provide for substantial replacement for the missing teeth with also added advantages when compared to fixed or implant prosthesis, mainly in elderly patients. Denture base material performance and durability are greatly influenced by wettability and water contact angle. In the case of dentures; adequate moisture distribution is necessary to ensure excellent wettability which has an influence on comfort and oral health. The purpose of conducting this study was to find out whether the advancements made using PEEK (Polyether ether ketone) would prove to be more beneficial than the current upgrades in the current material spectrum. MATERIALS AND METHODS: This study was performed under in vitro conditions. All the fabrication and processing was done only by one operator. The materials used were divided into three groups each comprising 20 samples. Group A was modified polymethylmethacrylate (Bredent Polyan), Group B was polyoxymethylene acetal resin (Biodentaplast) and Group C was PEEK. An Ossila Goniometer was used to measure the contact angle. The three types of liquids used for the testing included distilled water, natural saliva and mouth wetting solution (Wet Mouth Liquid, ICPA India). Human saliva was collected from an individual with no medical conditions and normal salivary secretion. RESULTS: The data was analyzed using One-way ANOVA test and a pairwise comparison using the Post Hoc Tukey's Honest Significant Difference. Table 1 consists of the mean water contact angles of the denture base materials and mean contact angles of various denture base materials. In saliva, mouth wetting solution and distilled water, the highest mean and least mean contact angle was seen in Polyan and Biodentaplast respectively. A signicant difference was seen between PEEK and Polyan and Biodentaplast and Polyan on further comparison. CONCLUSION: From the resources and the materials at our disposal, it could be concluded that Polyan, Biodentaplast and PEEK and could be used as viable options in cast partial denture framework.


Assuntos
Resinas Acrílicas , Benzofenonas , Polímeros , Polimetil Metacrilato , Bases de Dentadura , Prótese Parcial , Cetonas , Teste de Materiais , Metacrilatos , Polietilenoglicóis , Água , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...